COMPARISON OF COOLING LOAD CALCULATION METHODS BY
Abstract
AbstractThe present work includes cooling load measurement in Iraq. One room located in Baqubah was the object of the study. The measurement was taken for the room in summer months of 2004 (i.e. in May, June, July, August & September). The area of test room was 15 m2 and 3 m ceiling height with medium weight construction specifications. The test room includes exterior east and west wall facing, un-conditioning adjacent space with an exterior roof, east window and an exterior west door. The air conditioner unit used in this work was a window type with a nominal capacity of 2 T.R. (7 kW). The theoretical cooling load was predicted by three methods of cooling load calculation, which are TFM, CLTD/SCL/CLF & TETD/TA methods. Measurement of cooling load showed that there is a large difference between the measured and predicted cooling load with all theoretical methods. The difference ranged from 33% to 40%. This large difference is appear because of the several season such as the air conditioner type, suffer environmental and the construction specification of the test room where it’s represent the Iraqi building and not exactly same as building specification tabulated in ASHRAE tables
References
REFRENCES
ASHRAE Handbook - Fundamentals, American Society for Heating,
Refrigeration and Air Condition Engineers, Inc., New York
(1967).
ASHRAE Handbook - Fundamentals, American Society for Heating,
Refrigeration and Air Condition Engineers, Inc., New York
(1972).
ASHRAE Handbook - Fundamentals, American Society for Heating,
Refrigeration and Air Condition Engineers, Inc., New
York (1977).
ASHRAE “Cooling and Heating Load Calculation Manual”
American Society for Heating, Refrigeration and Air
Condition Engineers, Inc., New York (1979).
ASHRAE Handbook - Fundamentals, American Society for Heating,
Refrigeration and Air Condition Engineers, Inc., New York
(1981).
ASHRAE Handbook - Fundamentals, American Society for Heating,
Refrigeration and Air Condition Engineers, Inc., New York
(1997).
McQuiston, F. C. & Harris, S. M., “A study to categorize walls and
roofs on the basis of thermal response”, ASHRAE
Transactions, 94(2), 688 – 715 (1988).
Mitalas, G. P., & Stephenson, D. G. “Room Thermal Response
Factors”, ASHRAE Transactions, 73(II), III.2.1 - 2.10
(1967).
Mitalas, G. P., & Stephenson, D. G. “Calculation of heat conduction
transfer functions for multi - layer slabs”, ASHRAE
Transactions, 77(2), 117 – 126 (1971).
Romine, T. B. (Jr.). “Cooling Load Calculation”: Art or Science,
ASHRAE Journal, 34, 14 – 24 (1992).
Rudoy, W., & Duran, F. “Development of an Improved Cooling Load
Calculation Method”, ASHRAE Transactions, 81(2), 19 – 69
(1975).
Sowell, E. F., & Chiles, D. C. “Characterization of zone dynamic
response for CLF / CLTD tables”, ASHRAE Transactions,
(2A), 162 – 178 (1984a).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Prof. Dr. Khalid A. Joudi
This work is licensed under a Creative Commons Attribution 4.0 International License.